PHOENIX HARD-DRAWN COPPER TROLLEY WIRE

Grooved Wire Sections
|
Nominal size Awg |
00+ |
000+ |
0000+ |
||
|
Nominal area, cm |
133,200 |
168,100 |
211,600 |
300,000+ |
350,000+ |
|
Actual area, cm |
137,900 |
167,300 |
212,000 |
299,800 |
351,200 |
|
Actual area, sq. in |
.1083 |
.1314 |
.1665 |
.2355 |
.2758 |
|
Weight, lb. per 1000 feet * |
417.6 |
506.4 |
641.9 |
907.6 |
1063 |
|
Weight, lb. per mile |
2205 |
2674 |
3389 |
4792 |
5612 |
|
Minimum conductivity, % l.A.C.S |
97.16 |
97.16 |
97.16 |
97.16 |
97.16 |
|
D.C. resistance, ohms per 1000 ft at 20C (volts drop per ampere per 1000 ft) |
.07741 |
.06380 |
.05035 |
.03560 |
.03040 |
|
D.C. resistance, ohms per mile at 20C (volts drop per ampere per mile) |
.4087 |
.3369 |
.2659 |
.1880 |
.1605 |
|
Minimum tensile strength, lb. per sq. in |
50,200 |
48,500 |
46,600 |
44,200 |
42,800 |
|
Minimum breaking strength, lb. |
5437 |
6373 |
7759 |
10,410 |
11,800 |
|
Elongation, percent in 10 Inches |
2.80 |
3,25 |
3,75 |
4,50 |
4,50 |
·
Anaconda Standard - No Standard Figures Published by A.S.T.M.+ Use this value when specifying size on order.

Figure 9 Deep Sections
|
Nominal area, cm |
350,000+ |
400,000+ |
|
Actual area, cm |
348,900 |
397,300 |
|
Actual area, sq. In |
2740 |
.3120 |
|
Weight, lb. per 1000 feet |
1056 |
1202 |
|
Weight, lb. per mile |
5576 |
6347 |
|
Minimum conductivity, % I.A.C.S |
97.16 |
97.16 |
|
D.C. resistance, ohms per 1000 ft at 20C (Volts drop per ampere per 1000 ft) |
.03060 |
.02687 |
|
D.C. resistance, ohms per mile at 20C(Volts drop per ampere per mile) |
.1616 |
.1419 |
|
Minimum tensile strength, lb. per sq. In |
42,800 |
41,300 |
|
Minimum breaking strength, lb |
11,730 |
12,890 |
|
Elongation, percent in 10 Inches |
4.50 |
4.50 |
* Anaconda Standard - No Standard Figures Published by A.S.T.M.
+ Use this value when specifying size on order.